Our product range includes a wide range of ratnaflex single core cables, single core cables, h07v2-k single core cables, tri rated single core cables, h05z-k single core cables and rr kabel single core cables.

Ratnaflex Single Core Cables

REQUEST CALLBACK

Ratnaflex Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 500 / MeterGet Latest Price

Product Details:
BrandRR Kable
Number Of CoreSingle
Conductor TypeSolid
Length50-100 meter
InsulationYes
Shock ResistanceYes
Conductor MaterialCopper

Technical Specifications Conductor - Electrolytic grade annealed copper with high exibility Class 5 and uniform resistance properties. Conductor with Annealed tin copper can also be made available on request. Insulation - All insulation grades in PVC exceed the requirements as stated in IS 5831. All grades of insulation oered are RoHS compliant.Legends in Marking on Cable - RR KABEL, Ratnaex ISI, CM / L, CE Cable Colors - Available in Red, Yellow, Blue, Green, Green / Yellow, Grey & Black. Other colors available on request. Packing - Standard packing of 100 meters in coils. Longer length available as per request.
Data Chart Sizes, Dimensions and Ratings Ratnaflex (IS 694)
Part No.Nominal Cross Section mm²Nominal Overall Diameter (mm)
01 01 001C 0X500.52.1
01 01 001C 0X75 0.752.3
01 01 001C 0001 1.02.5
01 01 001C 01X5 1.53.0
01 01 001C 02X5 2.53.5
01 01 001C 0004 4.04.1
01 01 001C 0006 6.04.8
01 01 001C 0010 10.06.1
01 01 001C 0016 16.07.2
01 01 001C 0025 25.09.0
01 01 001C 0035 35.010.2
01 01 001C 0050 50.012.5
01 01 001C 007070.014.5
01 01 001C 0095 95.016.3
01 01 001C 0120120.018.0
01 01 001C 0150 150.020.0
01 01 001C 0185 185.022.3
01 01 001C 0240 24025.3
01 01 001C 0300 300.028.0
01 01 001C 0400 40033
01 01 001C 0500 500.037.0
01 01 001C 0630 630.041.5
Yes! I am interested

Single Core Cables

REQUEST CALLBACK

Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3.50 / MeterGet Latest Price

Product Details:
BrandRR Kable
Number Of CoreSingle
Length50-100 meter
ColorBlack
Shock ResistanceYes
Conductor MaterialCopper

Technical Specifications Applications -Cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Standards -BS/VDE EN 50525-2-31 Voltage Rating -0.5 to 1 mm² - 300/500V , 1.5 to 400SQmm² - 450/750V Conductor: Class 5 flexible plain/metal coated copper conductor to BS EN 60228:2005 (previously BS6360) Temperature Rating -Max rated for 90°C applications Insulation Colour -Black, Brown, Grey, Orange, Pink, Red, Violet, White Green/yellow Other Mono colors Yellow and Green are not covered in harmonization Insulation: -PVC (polyvinyl Chloride) TI3 to BS 50363-3 Minimum Bending Radius -6 x overall diameter CE= -The product conforms with the EC Low-Voltage Directive 2006/95/EC Properties -PVC self-extinguishing and flame retardant according to IEC 60332-1

Data Chart Sizes, Dimensions and Ratings H05V2-K
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
01 02 001C 0X50  1 x 0.50 2.10
 01 02 001C 0X75 1 x 0.75 2.30
 01 02 001C 0001 1 x 1 2.45
Yes! I am interested

H07V2-K Single Core Cables

REQUEST CALLBACK

H07V2-K Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 50 / MeterGet Latest Price

Product Details:
BrandRR Kable
Number Of CoreSingle
Conductor MaterialCopper
Length50-100 meter
ColorBlack
InsulationYes

Technical Specifications Applications -Cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Standards -BS/VDE EN 50525-2-31 Voltage Rating -0.5 to 1 mm² - 300/500V , 1.5 to 35 mm² - 450/750V Conductor: Class 5 flexible plain/metal coated copper conductor to BS EN 60228:2005 (previously BS6360) Temperature Rating -Max rated for 90°C applications Insulation Colour -Black, Brown, Grey, Orange, Pink, Red, Violet, White Green/yellow Other Mono colors Yellow and Green are not covered in harmonization Insulation: -PVC (polyvinyl Chloride) TI3 to BS 50363-3 Minimum Bending Radius -6 x overall diameter CE= -The product conforms with the EC Low-Voltage Directive 2006/95/EC Properties -PVC self-extinguishing and flame retardant according to IEC 60332-1

Data Chart Sizes, Dimensions and Ratings

H07V2-K
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
01 02 001C 01X51 x 1.53.0
01 02 001C 02X51 x 2.53.6
01 02 001C 00041 x 44.2
01 02 001C 00061 x 65.0
01 02 001C 00101 x 106.7
01 02 001C 00161 x 167.8
01 02 001C 00251 x 259.6
01 02 001C 00351 x 3510.5
Yes! I am interested

Tri Rated Single Core Cables

REQUEST CALLBACK

Tri Rated Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 500 / MeterGet Latest Price

Product Details:
BrandRR Kable
Number Of CoreSingle
Conductor TypeSolid
Conductor MaterialCopper
Length50-100 meter
Shock ResistanceYes
ColorRed

Technical Specifications Applications -For the internal wiring of panels, electrical equipment. Connection wire in machines laid in protective tubes and flexible pipes and also for motors and transformers.CE = The product conforms to Low-Voltage Directive 2006/95/EC Technical data - PVC-insulated flexible cables for Internal Wiring of Appliances. Temperature range: Flexing -5°C to 105°C, fixed installation -20°C to 105°C. Temperature at conductor: max. UL and CSA: 105°C. Nominal voltage: 600V. Test voltage:
  • (spark test) AWG 24: 4 kV, AWG 22 and 20: 5kV, AWG 18 to 16: 6kV, AWG 8: 7.5kV
  • UL-type AWM 105°C 600 V
  • CSA-type AWM 105°C 600 V
  • BS 6231 CK type 90°C 600 V
  • Bending radius: Fixed Application : 5 cable ø, Flexing : 10 cable ø
Cable construction-
  • Stranded copper conductor, plain or tinned to UL-Std. 758, CSA C 22.2 No.210-07 & BS 6231 approved
  • PVC-core insulation according to UL-Standard 1581, Class 43 and CSA-C22.2 No. 210 UL VW-1 and CSA FT-1, heat and damp resistant
Properties-
  • Conditionally resistant to Oils / Solvents / Acids / Dyes
  • PVC self-extinguishing and flame retardant, test method to UL VW-1 and CSA FT-1
  • Flame retardant to IEC 60332-1-2
Data Chart Sizes, Dimensions and Ratings
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
09 08 001C 0022  1 x 0.5 2.55
09 08 001C 0020 1 x 0.75 2.72
09 08 001C 0018 1 x 1 2.9
09 08 001C 0016   1 x 105 3.15
01 02 001C 0010  1 x 10 6.7
09 08 001C 0014 1 x 2.5 3.60
09 08 001C 0012 1 x 4 4.10
09 08 001C 0010   1 x 6 4.64
09 08 001C 0006   1 x 16 8.26
09 08 001C 0004 1 x 25 9.53
09 08 001C 0002 1 x 35 10.76
09 08 001C 0001 1 x 50 13.15
09 08 001C 2000 1 x 70 14.90
09 08 001C 3000 1 x 95 16.39
09 08 001C 4000 1 x 120 17.95
09 08 001C 0250 1 x 150 20.25
09 08 001C 0350 1 x 185 22.40
09 08 001C 0450 1 x 240 24.70
Yes! I am interested

H05Z-K Single Core Cables

REQUEST CALLBACK

H05Z-K Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 70 / MeterGet Latest Price

Product Details:
BrandRR Kable
Number Of CoreSingle
Conductor TypeSolid
Conductor MaterialCopper
Length50-100 meter
Shock ResistanceYes

Technical Specifications:
  • Applications: Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to be protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. The direct operating voltages is permitted up to 900 V against ground when they are used in rail-coaches. For the inner wiring of switch boards and distributors are to be used with an alternating nominal voltage up to 1000 V or a direct voltage up to 750 V against ground. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC Polyolefin cross linked -Insulated single core cables for low emission of smoke and corrosive gases in case of fire to DIN/BS EN 50525-3-41
  • Cable construction: Bare of tinned copper conductor, fine wire stranded according to DIN/BS EN 60228 cl. 5, Core identification according to DIN/BS EN 50525-1
  • Conductor Resistance: According to DIN/BS EN 60228 cl.5,r Temperature range -20°C to 90°C
  • Permissible working temperature: At the conductor 90°C
  • Nominal voltage -H05Z-K UO/U 300/500V, H07Z-K UO/U 450/750V,
  • Test voltage: 2500 V Minimum bending radius -approx 8 x cable ø
  • Tests: Self-extinguishing and flame retardant according to EN 60332-1-2
  • Ozone resistant: According to EN 60811-2-1 or HD 505.2.1 -Smoke density according to EN 61034-2

Data Chart Sizes, Dimensions and Ratings H05V2-K
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
01 02 001C 0X501 x 0.502.10
01 02 001C 0X751 x 0.752.30
01 02 001C 00011 x 12.45
Yes! I am interested

RR Kabel Single Core Cables

REQUEST CALLBACK

RR Kabel Single Core Cables
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 26 / MeterGet Latest Price

Product Details:
Minimum Order Quantity100 Meter
Wire Size4 sqmm
BrandRR Kable
Number Of CoreSingle
Insulation MaterialFR PVC
Conductor TypeMultstraind
Length50-100 meter
CertificationsIS 694
ColorBlack
Suitable forConstruction
Shock ResistanceYes
Conductor MaterialCopper
Country Of OriginMade in India

Technical Specifications Applications -Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to be protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. The direct operating voltages is permitted up to 900 V against ground when they are used in rail-coaches. For the inner wiring of switch boards and distributors are to be used with an alternating nominal voltage up to 1000 V or a direct voltage up to 750 V against ground. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC Halogen free thermoplastic -Insulated single core cables for low emission of smoke and corrosive gases in case of fire to DIN/BS EN 50525-3-31 Conductor Resistance -According to DIN/BS EN 60228 cl.5 Temperature range -20°C to 70°C Permissible working temperature -At the conductor 70°C Nominal voltage -H05Z1-K UO/U 300/500V, H07Z1-K UO/U 450/750V Test voltage -2500 V Minimum bending radius -approx 8 x cable ø Cable construction
  • Plain or tinned copper conductor, fine wire stranded according to DIN/BS EN 60228 cl. 5,
  • Core identification according to DIN/BS EN 50525-1
  • Core insulation of thermoplastic halogen free compound type TI7 to EN 50363-7
Core Colour -Black, GN/YL, Blue, Brown, Red, White, Grey, Violet, Dark Blue, Yellow, Orange LSOH -Low Smoke Zero Halogen-free Tests -
  • Self-extinguishing and flame retardant according to EN 60332-1-2.
  • Ozone resistant according to EN 60811-2-1 or HD 505.2.1.
  • Smoke density according to EN 61034-2
Data Chart Sizes, Dimensions and Ratings
H07Z1-K
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
01 02 001C 01X5 1 x 1.53.0
01 02 001C 02X51 x 2.53.6
01 02 001C 00041 x 44.2
01 02 001C 0006 1 x 65.0
01 02 001C 0010 1 x 106.7
01 02 001C 00161 x 167.8
01 02 001C 0025 1 x 259.6
01 02 001C 0035 1 x 3510.5
01 04 001C 0050 1 x 5013.0
01 04 001C 00701 x 7014.0
01 04 001C 00951 x 9516.2
01 04 001C 01201 x 12017.2
01 04 001C 01501 x 15020.0
01 04 001C 01851 x 18522.3
01 04 001C 0240 1 x 24025.3


Additional Information:

  • Delivery Time: 1-7 days
  • Packaging Details: 100mtr/500mtr
Yes! I am interested

CONTROL CABLE

REQUEST CALLBACK

CONTROL CABLE
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 30 / MeterGet Latest Price

Product Details:
BrandRR Kabel
Number of core1
ShapeRound
ColorBlack
Conductor TypeCopper

Technical Specifications Applications -Cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Insulation Colour -Black, Brown, Grey, Orange, Pink, Red, Violet, White Green/yellow Other Mono colors Yellow and Green are not covered in harmonization Insulation -PVC (polyvinyl Chloride) T12 to BS EN 50363- 3 Minimum Bending Radius -6 x overall diameter Voltage Rating -0.5 to 1 mm² - 300/500V, 1.5 to 240 mm² - 450/750V, Temperature Rating -Max rated for 70°C applications Standards -DIN EN 50525-2-31, VDE 0285-525-2-31, BS EN 50525-2-31 Conductor -Class 5 flexible plain/metal coated copper conductor to BS EN 60228:2005 (previously BS6360) CE= -The product conforms with the EC Low-Voltage Directive 2006/95/EC Properties -PVC self-extinguishing and flame retardant according to IEC 60332-1
Data Chart Sizes, Dimensions and Ratings

H07V-K
Part No.No. of Cores x Cross Sectional Area # x mm2Nominal Overall Diameter (mm)
01 02 001C 01X5  1 x 1.5 3.0
01 02 001C 02X5 1 x 2.5 3.6
01 02 001C 0004 1 x 4 4.2
01 02 001C 0006  1 x 6 5.0
01 02 001C 0010  1 x 10 6.7
01 02 001C 0016 1 x 16 7.8
01 02 001C 0025  1 x 25 9.6
01 02 001C 0035  1 x 35 10.5
01 02 001C 0050  1 x 50 13.0
01 02 001C 0070  1 x 70 14.0
01 02 001C 0095  1 x 95 16.2
01 02 001C 0120  1 x 120 17.2
01 02 001C 0150  1 x 150 20.0
01 02 001C 0185  1 x 185 22.3
01 02 001C 0240  1 x 240 25.3
Yes! I am interested

Rr House Wire 1 5mm 2mm 3mm 4mm

REQUEST CALLBACK

Approx. Rs 12.65 / MeterGet Latest Price

Product Details:

Wire Size1 sqmm
Insulation MaterialFR
Roll Length200 m
ConductorCopper
Number Of CoresSingle Core


FR 1.5 SQMM PVC IND CABLE (RED, BLK,B,Y,) 


Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Rahul Munot (Proprietor)
Radiant Electricals
547 A & B, Ground Floor, Nagnath Apartment, Budhwar Peth, Tapkir Galli,Besides Kasardevi Mandir, Tapkir Galli